If thats not the problem, then it could be that you replaced the motor with a full rated motor, but the impeller (and old motor) was an uprated motor, or vice-versa. It could also be something wrong with the motor, something internal with the windings, or shaft, or bearings, causing excess heat. Check all the power wires for tight fit and no corrosion. From the EcoStar technical guide: Check impeller and motor shaft for freedom of movement. 4. The pump acts like it wants to pump, but doesnt. To remedy this, simply open up your pump, and clean out any rubbish. Have a Hayward pump. Yes, very important to fill the pump up with water before running, or prime the pump from a bucket or garden hose. Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. I was just wondering if you thought that could be the issue unless it could be something else. Write Review Hayward AquaTrol HP Main PCB | GLX-PCB-TROL-HP $375.97 Quantity $17.35 / Month * Platinum Preferred Manufacturer Proposition 65 Warning 2. Check the pump lid o-ring or gasket, and be sure the lid is very tight. Hi Terri, when you connect the vacuum hose to the skimmer to start vacuuming, this is like increasing the length of the pipe from the pool to the pump, which makes the pump have to work harder, kind of like drinking through a very long straw. Hi Todd, ok I understand check the seal to make sure it is properly seated, and that the spring half is not turned backwards (should be hard plastic side toward motor, soft rubber side toward impeller, in most cases). Some advice? Then there is often a switch or a timeclock that is wired in between the sub-panel and the pump. My salt water pool was shut down for the winter. Hi again, I dont have a shaft seal replacement video, but there are many on youtube. Inspect the capacitor (black cylinder, 9 oclock) and the centrifugal switch, (on the end of the motor shaft), for any signs of damage or looseness. Diffuser broke. Power on LED is intermittently on or off. Any idea of the problem?? Motor was replaced then gfci breaker replaced to Hayward recommended breaker (same breaker I had first time) still tripping on every 4-5 days , 10 days inconstant times but again 99% of the time overnight. See if the pump motor shaft spins freely, to rule out a motion issue. The heat sink is a ridged metal plate beneath the drive, that relies on air flow to help remove heat from the motor. I took off the cover to see the circuit board and all looks ok but then it started coming on and off randomly while I was standing there. I added new wire and plug end but when I plug it in it trips the breaker. Thanks? please help. Hey John Should it be very hot to touch or is this an indicator for a capacitor problem? I remplace it and now the sistem works!! second most common is the pump lid or drain plug, lube the lid oring and teflon tape on the drain plug. Hi Jason, I would wait to spend the money, until certain that would be the fix. Hi Kathleen, sounds like a leak from the shaft seal, unless water is running out of the pump exit fitting, and running down the housing and dripping off the bottom. Hi Davy, I have a Hayward Super II which has been running well for years. in the filter. If your shaft IS spinning freely, other causes of a tripped breaker include loose wiring, broken wires, water in the wire conduit, wires inside the motor touching other wires or the metal motor casing, insect infestation in the time clock. Please remove additional products. "name": "Mark Garcia",
What am I missing? Hi Bobby, so you have power at the motor, but no noise. What could I be missing that would cause this? Hi Rick, if thats a new thing, there is probably something loose and leaking (air) when the pump shuts off. I changed the GFI Breaker in the main panel, problem still the same. This could drain the pool down to the skimmer, or possibly much lower in some cases, so keep a close eye on any leak and look for signs of worsening. If the new pump produces greater flow rate than the old pump, it produces high pressure, and poor filtration, and can damage the cartridge. 3. slide pump backwards, out of the housing, remove diffuser and wear ring from impeller Right now I can hear the pump running hard when it is turned on, but pressure gauge shows 0. Any ideas or what else to check? After connecting the device, the flow led flashes for one minute and turns off. Also, make sure you plug in the cell all the way. Suggestions on what to do next. This happens even when the filter and skimmer basket is clean. A leaking shaft seal should not cause your filter pressure to decrease. The filter timer will not turn on at all, even when trying manually but the cleaner does. Another reason for a smoking pump is an incorrectly installed shaft seal, or blown capacitor. Old broken wires inside of the conduit could be the problem. There should be no elbow after the flow switch. Usually however, a howling or moaning sound from the pool heater, is low water flow. Its linked to an AutoChlor switcher and comes on twice a day but failed to switch on a couple of days ago. Pumps normal pressure and pulls enough volume to keep bakery full. thank you Kelly. Thanks! It doesnt mean it is ready to go at 230. A hum sound is usually associated with a bad capacitor (motor rear, 9 oclock), however the capacitor is a battery that is only used on start-up, and is released within a second of start-up, but still could be related. Breville Tamper Coffee Kit 54mm, Hi I have a variable speed ecostar and am now having the drive error, drive stalled. I just had a power surge in my area and the heater has been turning on and wont turn off. Excessive voltage or amps can cause the problem. Or spray with shaving cream (yes! Not that I can think of, but something seems to be aerating your water? I tried to prime the pump but it still doesnt kick over to cycle anything. thanks. Flip timeclock switch on, inspect time clock motor gears (Intermatic clocks) for good timer motor, and inspect wiring from timer to pump. Have no power at all going to my control panel. It looks like its coming from in between the motor and pump.Am I correct in thinking I need a new seal plate kit? So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. If not, but the shaft and impeller spin freely remove the start capacitor, normally located in the motor rear, at 9 oclock, and write down the MFD number, and then order one online, or at a local electric motor repair shop. Without seeing the union and setup, it is hard to say what is causing it but check for warping of the nut. But most aboveground pool pumps are 115V, and certainly is if it came with the cord. I calibrated the unit to 3100 ppm. Sounds like you might have enough good parts to put together one good pump! "caption": "In The Swim Blog"
Hi Donna, the screws that are removed to rotate are the long thru-bolts that run thru the motor, and are turned at the rear of the motor (spray with WD-40 first). Could vibration over time wear the pump housing? When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. Increased flow this year may be from the new sand, and higher flow makes it easier for air leaks to appear. I couldnt believe it..after two weeks and a new pump! But lack of sand should not cause a leaking problem. When we turned it on heard a pop and blew fuse. last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. I think it only screws on in one direction, but unscrew it to check When in Filter Position, water should route in only one direction. What am I doing wrong?? Check electrical connections and wiring for loose or broken. Hi Virgil, the time clock may not be set, or if you have a controller, the on/off program may not be setup, so it runs until it is set to turn off but is not set to turn back on again? Thanks! After running the pool for a few hours we realized the pump was leaking and EXTREMELY HOT. Other causes of high pressure could be unrelated to the pump size, such as an obstruction or restriction on the return line, or a partially closed valve, or plugged wall returns, or eyeball fittings in the pool that are too small. Replaced the flow sensor as it seemed to run when lower RPMs on the pump and it now seems to cut it off when the RPMs on the pump drop like it should, and it will cut off when temperature reaches set heat of 93 for the spa. I replaced the rod, and now my lid will not go down, the rod is the exact same as the other. Is the shaft spinning freely? I have a Hayward sp 2603 vsp pump which is a year old has been working fine but 2 days ago I turned it on it ran about 1 minute, it cut off and on the display it says error code 11 and it will not run. Ive checked all my hoses for clogs and skimmer and pump baskets are clean. Normally they last longer. I put a new power cord socket in the water proof box, which feeds power to the pump, I shined up the power cord plug pins), (power cord is about 2.5 ft of 12 Ga, not wet, not laying on the ground) Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). It should be the receiving 115V or 230V, depending on how it is wired, plus/minus 10%. Hi Matt, sound like the bearings have gone bad, and now they are so bad that the shaft has locked up or is binding, and that trips the breaker. Have a Hayward SuperPump. I have a F5 code and service light is on. Monday Friday, 8 AM 5 PM. ), to see if air is drawing in around the fitting. How To Identify The Problem Look at all the metal components in and around your swimming pool. Verify if your flow switch was installed correctly. Dont let pool pump problems drive you crazy! Drive Error is a major fault. Step 4: If none of the previous steps solved the problem, replace your flow switch. Tested the switch on and off and it works as expected. Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. 20amp fuse is not blown. A pump that simply wont start is a frustrating problem. Hi Robin, an F5 code? When it gets up to speed, the switch is supposed to release the capacitor. Im losing my mind. Holding the shaft stationary (so it wont turn), unthread the impeller, counter clockwise, to remove. It was only 3 years old. It can also be a loose pump lid allowing air to creep in around the o-ring. We are headquartered in Valley Stream, New York, just outside of New UNK the , . Hi Jeff, probably that sound is worn bearings (pumps dont have brushes). 12 ga or 14 ga? I have replaced my existing super pump with new one. Previous pump 15 years old no problems vacuuming, Can there be a high resistance leak in the lines or pump only when connecting the vacuum ? It could also be a bad capacitor, which is like a battery, to start the motor. Gail, good luck! This week I notices that if I turn down the chlorine production rate.the display stops at 5I can no longer get it to zero.I know I can turn off production by sliding the button downbut should I be worried? Also check other wires in the back of the motor. Hi Mike, it could be the start capacitor going, or it could be that one of the bearings is not quite perfectly flat, and if the shaft stops rotating at the right spot, it has trouble making the shaft turn, until bumped. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
6. Finally, could be that the voltage is not quite right, one of the legs (power wires) not providing enough power. When I then switch the pump breaker off and then back on again it springs into life (every time). Im not sure how the filters went bad being winterized, but they were way old. Hi the strainer housing must need to be tightened up. In most cases, it means that your motor is on the way out. . Sounds like maybe youve tried it both ways, at water level and below water level? Good luck! Once I get it going, it works fine for as long as I leave it on. The problem lies, where the power dies could be the breaker, time clock, outlet or at the terminal board. We had a pool built in FL in Aug 2018 with variable speed Hayward TriStar pump. On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. Theres not much room back there for wires, and if they get too close to other things. Hi Thomas, the fitting that goes into the pump, was it also replaced? Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. We have a few of them, but maybe not the correct one for your motor, replace with the exact same MFD number, printed on the cap. I put a new 1 hp motor on the pump, and new mechanical seal in the pump, problem still the same. if it does not come back on, check switches, turn breaker all the way off and back on again. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. LibriVox About. It worked fine just prior to a filter cleaning. I turned it off overnight but still the same thing. Just wired and installed a brand new Century 1 hp pump motor on a Hayward Super pump filter, getting power to the terminals of the motor but motor does not start, shaft spins freely. Hi Davy, Air leaks or other obstructions BEFORE the pump (including a clogged impeller), will cause lower than normal filter pressure. The GFI doesnt break which is where the pump is plugged into, it is just the breaker on the eletrical box that pops. At the end of last season we noticed a leak. I disconnected it and plugged the Aquatrol in alone; that worked fine. Dec 14, 2021. When you start the pump on low, on the panel it does say load 2 and load 3, "on". Any idea what the next most likely culprit could be? Lighting, Learn About "url": "https://blog.intheswim.com/"
Hi, We had a pool installed last fall and we are still figuring things out. Next, check continuity from lead to lead. It was wired for 230 but only had 115 going into it (we realized this after we had a pool guy come and see it) for a long time. https://twitter.com/inyopoolsFOLLOW us on INSTAGRAM! Check in morning and basket is half full with water trickling in basket. Informacin detallada del sitio web y la empresa: cd77petanque.com Comit de seine et marne de ptanque Strange things that when I have a storm it doesnt break but I does a day after when day is perfect. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have 25 The following steps will provide a guide on how to recalibrate a Hayward Aqua Rite. Sometimes you can reposition it, or reglue it, or make it work for a little while longer, while you order the correct spider gasket to match your make/model of valve. Hi Anmarie, Could be the wrong type of sand, but not likely if the bag said Pool Filter Sand on the label. When it stops again, you may want to pull off the filter valve from the filter, and inspect the top few inches of sand, maybe replacing it with new. Pump is grounded. I have a max-flo XL pump how high should it read it keeps going over 20 psi is this normal. Have a brand new Hayward power flo LX. If it an older installation, I would again check the water chemistry to make sure it is balanced correctly. Grab it and see if it looks/feels loose. Only get big time cavitation and the basket empties about half. I only rotated the one piece how can the screws not go right back in? A corroded part will be rusted and will start to disintegrate over time. Reprime the pump again, open water valves and test. Is it a defective motor or something else? Some pumps are stronger than some hose, so check to see if the hose is not collapsing under the suction, during the issue. Heyward 1.5 hp runs for a while and then top of pump pops off when I reset it works for a while and then pops again could It be pressure building up due to dirty filter? to turn off the timer. Thanks. The problem lies, where the power dies as they say. If you havent inspected your cell yet, now is aperfect time. Nothing your husband did, hes safe to come out of the doghouse, lol. We have a circuit board that controls these two motors as well as an LED light. Mine hums and then trips the breaker. The pump has been running for 2 days. 9,000 gallon in ground pool. Oftentimes I reassemble the pump only to find the diffuser laying on the ground (doh!). Davy, If i knew what make/model of pump you have, I could be more specific. I checked the pump and is is very hot. Capacitor or needs new motor?? It would be best to not abandon the pipe if possible, best for water quality, clarity and turnover rates but sometimes thats not feasible so either way will work! The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. Wait for the relay to click (5 to 10 seconds). Nothin seems to be leaking anywhere. Now if you do find power at the motor, and the wires are screwed tightly, but no sound, no movement, and the breaker doesnt trip it could be a bad motor. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. Could also be low water level in the pool, or a stuck skimmer weir, blocking water flow. If the impeller spins freely, does that mean the shaft is spinning freely or do I need to try to turn it from the back of the motor? Is it plug and play? Thanks. If you lose suction, and the pressure gauge is normal, or lower than normal, that would indicate an air leak in the hose or pipe, or pump, or a clogged pump basket. Check the switches in the back of the motor, the centrifugal on the end of the shaft, and the stationary, mounted at 6 oclock, to look for any loose screws or insects, or mis-alignment. the loosed its prime again. Can I turn on this pump without water to check whether the motor is running? Then, take a look at the capacitor, located at 9 oclock. Do you know what the suggested torque is for the housing cap screws? 6. inspect conduit and wires going from timer to pump, look for water in the conduit, or broken conduit, or rodent damage to wires. 5. The process, for changing a hayward pump seal is: 1. Is there something I forgot to do? Look closely for any visible damage in the rear of the motor, anything loose, disconnected, chewed, melted, broken, burnt or cracked. Specialties: Cycling, Kickboxing, The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. But not likely, since its been there for years. 7. inspect breaker, turn off breaker to pool from house main panel). Hi. "dateModified": "05/20/2022",
The leak at the bottom of the pump, determine if its coming from the top of the pump and dripping down the sides, or if the leak is coming from directly under the pump, in the first case its usually the exit pipe threads are loose, and in the second case, its a leaking shaft seal or leaking drain plug, or sometimes a leaking volute o-ring, or the large o-ring between the seal plate and the pump housing. We live in Arizona, so the automatic freeze setting isnt an issue. Turned on the motor and smoke and a oil type substance came out of the capacitor. Second thought is are the pipes plumbed into the valve correct? I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. This noise does not happen when the water is flowing through the heater but it is not turned on. Inspect the capacitor, or have it tested, or just replace with same MFD rating shown. If power is reaching the box, getting past the transformer, and the fuse is good, it sounds like the main PCB is the issue. I have a Hayward Super Pump Model:C48L2N134B1 that I replaced 3 or 4 seasons ago and until now I have had no trouble out of it. Hello , This is an inactive thread. Hi Kacy, thats very odd, and likely just a coincidence that the pump works on backwash only. A pool guy who has since stopped operating put it in. I have a Hayward H250, when I turn it on the green heat light is lit and the heater seems to make a howling sound. Drain plugs, pump lid, pipe coming into pump, skimmer or main drain valves, low water level, stuck skimmer weir, or the dreaded underground cracks in pipe (rare problem). We just opened our pool up cleaned everything out put new D.E. But just like any sort of equipment, even the most well-made products sometimes need repairs. Usually get 3-4x that long. Are you using DE powder or enough DE powder? Look closely at the suction-side (incoming pipes/valves, up to the strainer pot), and shut off pump, watching closely for water spray, or sometimes just a fast dribble. I just dont know when it was purchased or how to even find out from the previous owners. Motor may still be good. Filters, Learn About Vacuum hose air leaks from splits in an old hose. Motors have a thermal overload switch (in the rear of the motor, top-dead-center, at 12:00). They have to stick out about 1/8 wider than the plunger disk. How do I get the lid tight enough? 4. remove rear motor cover, loosen screw that holds capacitor (9 oclock) and move it out of the way, so you can fit a 7/16 wrench on the rear of the motor shaft, behind the centrifugal switch. Too bad Hayward doesnt make this more clear on their installation instructions and labeling. When I turned the pump on it is very loud and the pump is not moving water. that is quite unusual, the 3/4 hp Super II is designed to pull much less, probably around 12 amps. Also check the pump basket, and possibly the pump impeller may be clogged, but Id first clean the filter. You must log in or register to reply here. hI, the impeller ring should go small side toward the impeller, they are often marked as such. What do you think is the problem? Might be some voltage issues? Check the shaft for free spinning movement, and check the capacitor for signs of failure (bulges, cracks, smoke). I recently took it ofdf to install a new spider gasket and saw no obvious reason for the leak. Just bought a hayward super II pump. See below for more detail. Shut down the power to the pump from the breaker for 15 minutes turn back on and try to run the pump. If clogged, open the pump up, and ream out the impeller vanes with a flexible wire. The air may be there on high speed too, its just not noticeable. Long story short, bought a house that had an above ground pool that would not get the pool clear. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. Hi Bryan, not normal but not uncommon. "identifier": ""
Could it have shut it self off from overheating? JUst installed new heyward pump . When pump start it work fine but after few hours water stop moving. If no, test power on the wires coming into the pump, place test meter leads on the red and black wires, with power turned on to the pump. Hmmm, now if the breaker were stopping the power from flowing to the switch, the timeclock would lose time, and would not turn itself on. Fix this problem simply by tightening or adjusting the wires and connections in the motor. Shut off power at the breaker to all pool equipment Some inground pools used Flex PVC pipe to connect skimmers, and over 20-30 years, Flex pipe can develop internal nodules like polyps, that restrict flow. Just replaced a 1.5 hp Hayward super pump with a 1 hp Hayward super pump. Per your article, it sounds like I need a new capacitor. My Hayward xstream filter pump is not turning on at all. I have a Hayward Self Priming Super Pump Model # C48J2N131B1. Second thing could be loose wire connections, on the breaker, on the outlet, or on the cords connecting to the pump/trol, or damaged plug ends. it does not turn on even though i get 240 volts.My blower is on a different circuit and works properly with 240 volts.